b'Louvre fixed into precast panel with suredriveanchors @ 400mm c/c. Approved waterproof membrane to entireopening of precast panel.Osbournes Model WPL Closeable(Channel). Sikaflex-20AT or similar approved sealant atSikaflex-20AT or similar approved sealant at louvre/panel junction on PEF backing rod topanel/louvre junction to rear of louvre to match ratio of 2:1 installed to manufacturersexterior. 25 recommendations. Provide weepholes insealant at either end of louvre.Plastic shims to suit. Provide 5 slope to sill.variesPrecast panel to Engineers design anddocumentation.Model WPL Closeable (Channel Frame)Typical Precast/Louvre Sill Detail 03Osbournes LtdScale 1:5General Notes:Flashing materials must be selected based on environmental exposure, refer to NZS 3604:1999.Refer to the manufacturer or supplier for technical information of all materials.This is an untested alternative solution to NZBC E2/AS1.This information is intended to be informative and used as a guideline only. Due to the many variables affecting different projectsOsbournes Ltd can not replace the judgment or advice of an Architect, Engineer or any other relevanttechnical expert and such experts must be consulted to determine the suitability or otherwise of the details or the necessity forfurther design/detailing.Page 66'